i bc27f85be50b71b1 (262 page)

BOOK: i bc27f85be50b71b1
13.72Mb size Format: txt, pdf, ePub

APPENDIX III-C: CIRCULATORY ASSIST DEVICES

835

Table Ill-C. I. Ventricular Assist Devices (VADs)

Pump

Pump Name

Mechanism

Use

Internal VADs

HearrM:ne

Pneumatic

Left ventricle

or electric

Novacor

Electric

Left vencricle

SymbioniCardio We"

Pneumatic

BOth ventricles

rorally artificial heart

External VADs

Bio-Medicus

Centrifugal

Right or left ventricle, or

both

Thocatec

Pneumatic

Right or left ventricle, or

both

Hemopump

Axial flow

Left ventricle

Abiomed BVAD 5000

Pneumatic

Right or left ventricle, or

both

Sources: D;Ha from EF Bond, J Da:<. Nursing Man3gemem Crirical Care. In SM Lewis,

MM Heitkempcr, SR Dirksen (cds), Medical Surgical Nursing: Assessment and Management of linical Problems (5th cd). St. Louis: Mosby, 2000;1926-1927; and NG Smedira, Rl V:ugo, PM McCarthy. Mechanical Support Devices for End-Stage Heart Failure. In Dl

Brown (cd), C1rdiac Inrensive Care. Philadelphia: Saunders, 1998;697-703.

The following are general considerations for the physical therapist

working with a patient on a VAD:


The patient'S native heart is still contracting (albeit ineffectively)

and, therefore, the patient'S electrocardiogram will reflect the

native heart's electrical activity. However, because the VAD is performing a majority of the patient'S cardiac output, the patient's peripheral pulse is indicative of the rate set on the VAD.'


The rate on a VAD can be fixed or automatic. VADs that have

automatic rates are able to adjust their rate according to the

patient'S needs (i.e., increase with exercise).3.4


Patients typically complain of pain at the insertion site of access

lines in the abdomen and may need appropriate premedication

with analgesics before therapy.s

836 ACUTE CARE HAND800K FOR PHYSICAL THERA1)ISTS


Certain VADs have a manual mechanical pump feature in case

the VAD malfunctions. Therapists working with these patients need

to be trained on how to use this critically important safety feature."


A patient who demonstrates the following hemodynamic variables should have physical therapy deferred until he or she i more stable4:

a.

LVAD rate <50 beats per minute

b.

LVAD volumes dO ml

c.

LVAD flows d.O liters per minute

d.

Systolic blood pressure <80 mm Hg

e.

Heart rate (native) > 150 beats per minute

f.

Sustained ventricular tachycardia or venrricular fibrillation

Extracorporal Membrane Oxygenation

ECMO involves the use of a device external to the body for direct

oxygenation of blood, assistance with the removal of carbon dioxide,

or both. The primary indication for ECMO is cardiac or respiratory

failure that is not responding to maximal medical therapy. The pediatric population with respiratory failure seems to benefit from this therapy the most; however, the successful use of ECMO in the adult

population is improvingJ-9

Patient situations that are likely to require ECMO include the following:


Postcardiotomy cardiac or pulmonary support


Cardiac arrest


Cardiogenic shock


Primary respiratory failure


The period after lung or heart transplantation or LVAD

placement

The ECMO system consists of a venous drainage cannula, a reservoir for blood, a pumping device that uses a centrifugal or a roller system, an oxygenator, and an arterial or a second venous return can-

Arl'ENDIX III-C: CIRCULATORY ASSIST DEVICES 837

nula.- The pumping device is used to help a failing ventricle circulate

blood, whereas the oxygenator device assists the failing respiratory

system to fully oxygenate the patient. Patients who have respiratory

failure require concurrent mechanical ventilation ro prevenr atelectasis while on ECMO. However, less positive pressure is required to oxygenate blood when on ECMO, resulting in a decreased incidence

of barotrauma.2•7

The system that uses the venous drainage to arterial return cannula

(V-A mode) is primarily performed on patients who require cardiac or

cardiorespiratory support. The V-A mode can be achieved in three ways':

I.

Femoral vein to the ECMO system back to the femoral

artery

2.

Right atrium to the ECMO system back to the ascend-

ing aorta

3 . Femoral vein to the ECMO system back to the ascend-

ing aOrta

The system that lIses the venous drainage to venous rerum cannula

(V-V mode) is primarily used for patients who only have respiratory

failure. The V-V mode can be achieved in twO ways':

I.

Internal jugular vein to the ECMO system back to the

common femoral vein

2.

Common femoral vein drainage to the ECMO system

back to the concralateral common femoral vein

Patients who are on V-A mode ECMO are typically anticoagulated

with heparin and may require the use of IABP to further assist the

ventricle. Patients on the v-v mode may require sedation and or medical paralysis ro help improve oxygenation to organs and tissues by minimizing the metabolic demands of an awake person.'

Complications of ECMO include lower limb ischemia, thrombocyropenia, thromboembolism, and failure of the oxygenaror device.9

General Physical Therapy Considerations


Patients requiring the use of circulatory assist devices are typically on bed rest, and physical therapy usually consists of bron-

838 AClITE CARE HANDBOOK FOR PHYSICAL THERAPISTS

chopulmonary hygiene and airway clearance, along with the

prevention of secondary complications of bed rest, such as joint

contracture and skin breakdown.


Special care should be taken to avoid disruption of the tubes

associated with these devices.


Range-of-motion exercises should not be performed on extremities with ECMO catheters unless otherwise cleared by the physician.


Patients with an internal or external VAD who are allowed out

of bed should progress their activity very gradually with careful

monitoring of vital signs and Borg's rating of perceived exertion.

References

1. Mahaffey KW, Kruse KR, Ohman EM. Intra-aortic Balloon Pump

Counterpulsation: Physiology, Parient Management, and Clinical Efficacy. In DL Brown (ed), Cardiac Intensive Care. Philadelphia: Saunders, 1998;647-653.

2. Bond EF, Dax J. Nursing Management; Critical Care. In SM Lewis, MM

Heitkemper, SR Dirksen (eds), In Medical Surgical Nursing: Assessment

and Management of Clinical Problems (5th edl. Sr. Louis: Mosby,

2000;1926-1927.

3. Smedira NG, Vargo RL, McCarthy PM. Mechanical Support Devices

for End-Stage Heart Failure. In DL Brown (cd), Cardiac Intensive Care.

Philadelphia: Saunders, 1998;697-703.

4. Humphrey R, Buck L, Cahalin L, Morrone T. Physical therapy assessment and intervention for patients with left ventricular assist devices.

Cardiopulmonary Phys Ther 1998;9(21:3-7.

5. Buck LA. Physical therapy management of three patients following left

ventricular assist device implantation: a case report. Cardiopulmonary

Phys Ther 1998;9(2):8-14.

6. Morrone TM, Buck LA, Catanese KA, ct al. Early progressive mobilization of patients with left ventricular assist devices is safe and optimizes recovery before heart transplantation. J Heart Lung Transplant

1996;15:423-429.

7. Kaplan RJ, Smedira NG. Extracorporeal Membrane Oxygenation in

Adults. In OJ Goldstein, Me Oz (cds), Cardiac Assist Devices. Armonk,

NY: Furura Publishing, 2000;263-273.

8. Mulroy J. Acute Respiratory Distress Syndrome. In L Bucher, S

Melander (cds), Critical Care Nursing. Philadelphia: Saunders, t 999;

457-458.

9. Copeland JG, Smirh RG (cds). Bridge to Transplanrarion with Mechanical Assist Devices. New York: McGraw-Hili, 2000.

IV

Pharmacologic Agents

Jaime C. Paz and Michele P. West

Pharmacologic Agents

Other books

The Chasm of Doom by Joe Dever
Case with 4 Clowns by Bruce, Leo
The Heist by Janet Evanovich
Trial by Fire by Terri Blackstock
A Woman Made for Pleasure by Michele Sinclair
Mind Magic by Eileen Wilks
The Da Vinci Cook by Joanne Pence
Run (Nola Zombies Book 1) by Zane, Gillian